Pipe size: And milking machine airflow
Authors
R. N. EideW. C. Fairbank
Authors Affiliations
R. N. Eide is Dairy Farm Advisor, Fresno County; W. C. Fairbank is Extension Agricultural Engineering Technologist, University of California, Davis.Publication Information
Hilgardia 16(7):12-13. DOI:10.3733/ca.v016n07p12. July 1962.
PDF of full article, Cite this article
Abstract
Improper pipe size is a common fault of vacuum supply systems on California dairies. Data presented in this study indicate that a minimum vacuum supply pipe diameter of 1 1/4 inches is needed to handle four or five milking units and 2-inch pipe is the minimum size required for 7 to 12 units.
Eide R, Fairbank W. 1962. Pipe size: And milking machine airflow. Hilgardia 16(7):12-13. DOI:10.3733/ca.v016n07p12
Also in this issue:
Climatic zones for turfgrass in CaliforniaMeat-type lambs: —Goal of proposed sheep improvement association
Severe copper deficiency: Identified in southern California grapefruit
Imperial Valley Field Station Division of Agricultural Sciences University of California El Centro California
EPTC: Pre-emergence herbicide aids establishment of clovers in dryland pastures
Grape container Testing: In simulated transit laboratory shows severe vibration injury possible in loose-packed fruit
Effect of downy mildew on productivity of sugar beets, and selection for resistance
Certain symptoms resembling those of curly top or aster yellows, induced by saliva of Xerophloea vanduzeei